info@redvancetech.com +86 135 3679 1558 OEM / ODM Manufacturer · Shenzhen
 
Sourcing / Supplier Capability / LED Manufacturing

A grow light factory already knows high-power LEDs, drivers and heat sinks. It may not know how to light a person. Horticulture measures photons across a plant canopy for hours a day. Red light therapy measures energy at a person’s skin, at close range, for minutes. Some of the skills carry over and some do not, and the spec sheet language usually tells you which side a supplier is really on.

Some LED manufacturers that built their business on horticultural lighting also sell red light panels and full-body devices. On paper the move is short: the same red LEDs, similar aluminium housings, drivers that run for thousands of hours. Some of these factories are capable PBM suppliers. Others are selling grow light engineering with a new product name.

This guide sets out where the two fields differ, why a grow light metric says almost nothing about a red light device, what transfers, what does not, and the questions that separate the two. It is part of our ODM platform verification series.

Short answer

Ask the supplier to describe its red light device in red light terms: irradiance in mW/cm² at a stated distance, peak wavelength and tolerance for each red and near-infrared band, flicker, EMF at the user’s position, and a photobiological safety assessment for human use. A factory that answers in PPFD, µmol/J and canopy coverage is still speaking horticulture. LED sourcing, thermal design and driver reliability usually transfer. Near-infrared spectral control, near-field uniformity and human-facing safety have to be shown.

01

Same LEDs, two different jobs

Design questionHorticultural lightingRed light therapy device
TargetA plant canopyA person’s skin
Main quantityPhoton flux in the 400 to 700 nm band, as PPF or PPFD in µmol/s or µmol/m²/sIrradiance in mW/cm² across the specified red and near-infrared bands
WavelengthsBlue, red and often far-red, chosen for plant responseSpecified red and near-infrared peaks, such as 630, 660, 810, 830 or 850 nm
DistanceCanopy height, often well above the plants, uniform over a large areaClose range on a body, often around 15 cm or less
ExposureHours per dayMinutes per session
Who is near the lightWorkers passing throughA user facing the light at close range for the whole session
Figure of meritPhoton efficacy in µmol/JDelivered irradiance, spectral accuracy, flicker, EMF and safety at the user

The LEDs can be the same parts. The design targets around them are not. Industry standards work on plant lighting moved away from human-based units like lumens because they say little about plant growth. The same logic runs in reverse: plant units say little about a device built for people.

02

Why a PPFD number tells you almost nothing

PPFD counts photons between 400 and 700 nm. Two problems follow for a red light device.

Near-infrared is not counted

The 810, 830 and 850 nm bands in a typical red light panel sit outside the 400 to 700 nm range. A PAR quantum sensor is designed for that range, so a high PPFD reading says nothing about the near-infrared half of the device.

Photons and energy do not convert without the spectrum

Each photon’s energy depends on its wavelength. At 660 nm, 1 mW/cm² corresponds to about 55 µmol/m²/s. At 630 nm the same irradiance is about 53 µmol/m²/s, and at 850 nm about 71. A mixed-wavelength PPFD figure cannot be turned into mW/cm² unless you know exactly how the light is split across wavelengths.

Calculated from photon energy at each wavelength. For conversion only; not a measurement of any product.

Metric rule: for a red light device, ask for irradiance in mW/cm² at a stated distance, measured with a method suited to the full spectrum, plus a spectrum report. Any figure in µmol is a horticulture figure.

For what a credible irradiance figure looks like, see red light therapy irradiance in mW/cm² and how to read an irradiance test report.

03

What usually transfers, and what has to be shown

CapabilityFrom horticultureWhat to check
High-power LED sourcing and binningUsually transfersWhether it extends to near-infrared parts at the wavelengths you specify
Thermal management of LED arraysUsually transfersSurface temperature on the user side, not just LED life
Driver efficiency and long-life reliabilityUsually transfersFlicker and EMF, which plant lights rarely need to control
Near-infrared spectral controlMust be shownPeak wavelength and tolerance for each band, from a spectrum report
Near-field uniformityMust be shownOptics designed for canopy distance can leave hot spots at 15 cm
Flicker at the userMust be shownMeasured flicker in every mode, especially dimmed modes
EMF at the user’s positionMust be shownMeasured at the distance the user sits
Photobiological safety for human useSeparate workAn IEC 62471 assessment for the device’s configuration and operating distance
Claims disciplineSeparate workYield claims for plants are commercial; claims about people are regulated

Dimming is a good example of a hidden gap. Grow lights are often dimmed, and plants are not troubled by how that is done. A person sitting in front of a dimmed panel is a different case, which is why flicker needs to be measured in every operating mode. Our article on EMF, flicker and heat explains what to look for, and our guide to spectrum reports and wavelength tolerance covers the spectral checks.

04

Reading a crossover supplier’s marketing

The checks in our platform verification hub apply here with a few additions.

  • Check which product line the certificates cover. A quality system certificate or test report issued for horticultural luminaires does not cover a device used on people. Read the scope and the product named.
  • Check which line the photos show. Factory floor images of grow light production are evidence of grow light capacity.
  • Check the dates. A press release describing a trade show launch should line up with the organiser’s event dates.
  • Check the language. Coverage area, mounting height and µmol/J on a red light product page are signs the device was specified by a horticulture team.
  • Check the ownership history. Business registration records show what the company was set up to do, and whether the red light business sits in the same entity. See how to verify a Chinese factory’s business registration.

None of these rules a supplier out. A horticulture factory with real near-infrared, flicker and safety data is a serious option. The point is to see the data, not the transition story.

05

Questions that separate the two

Supplier questions

Grow light factory or PBM supplier?

  1. Irradiance: mW/cm² at a stated distance, with the meter and method, for the device you are buying.
  2. Spectrum: a spectrum report showing peak wavelength and tolerance for every red and near-infrared band.
  3. Flicker: measured flicker in every mode, including dimmed modes.
  4. EMF: measured at the position the user occupies.
  5. Photobiological safety: an IEC 62471 assessment for this device, at its operating distance.
  6. Uniformity: irradiance across the treatment area at the use distance, not across a canopy.
  7. Track record: how many human-facing devices the factory has shipped, and who designed their drivers and firmware.

If the answers come back in PPFD, coverage area and photon efficacy, the device was designed by a horticulture team. That may be fine for its housing and heat sink. It is not evidence about what reaches the user.

06

The rest of this series

07

Where RedVance stands

We specify our panels in human terms because that is what they are built for. For our LED60, the measured figures answer the first questions on the list above: 190 mW/cm² at 15 cm, 60 dual-chip LEDs across five wavelengths at 630, 660, 810, 830 and 850 nm, a flicker-free driver and near-zero EMF.

We design and build our own driver boards and firmware, so flicker and EMF are design decisions we control, not properties we inherit from someone else’s platform. If you are comparing us with a crossover supplier, send us both sets of documents and we will tell you, line by line, which questions each one answers. Our OEM/ODM programme covers how projects are scoped.

Frequently asked questions

How do I verify a grow light supplier can build a red light therapy device?

Ask for the device’s specification in red light terms: irradiance in mW/cm² at a stated distance, peak wavelength and tolerance for each band, flicker in every mode, EMF at the user, and an IEC 62471 assessment for human use. Answers in PPFD and coverage area mean the device was specified for plants.

How do I verify whether a PPFD figure tells me anything about a red light panel?

Check the wavelength range. PPFD counts photons between 400 and 700 nm, so it leaves out the 810 to 850 nm near-infrared bands entirely. It also cannot be converted to mW/cm² without the full spectrum, because photon energy changes with wavelength.

How do I verify a supplier’s near-infrared LEDs match their stated wavelengths?

Ask for a spectrum report for the device, not the LED datasheet, showing the measured peak wavelength and tolerance for each near-infrared band. Plant lighting rarely uses the 810 to 850 nm range, so this is where a horticulture supplier has the least track record to show.

How do I verify a crossover supplier’s certificates cover a red light device?

Read the scope and product named on each certificate and test report. A quality certificate or test report issued for horticultural luminaires does not cover a device used on people. Ask for documents naming the red light device you are buying.

How do I verify a grow light supplier has controlled flicker for human use?

Ask for flicker measurements in every operating mode, including dimmed modes, on the device you are buying. Plant lights are often dimmed in ways plants do not notice, so flicker control is a design step a horticulture team may not have needed before.

How do I verify a red light device is uniform at close range?

Ask for irradiance measured at several points across the treatment area at the actual use distance, such as 15 cm. Optics designed to spread light evenly over a plant canopy at height can leave bright and dim zones when a person sits close to the panel.

RedVance / Supplier comparison

Send us the spec sheet you were given. We will show which questions it answers and which it skips.

Share a crossover supplier’s datasheet, test reports or product page. We will mark which figures describe what reaches a person and which describe a plant canopy, and tell you honestly where our LED60 data compares and where it does not.

Compare supplier specs →
Sources

PPF and PPFD based on the 400 to 700 nm band, and plant lighting standards work: LEDs Magazine on ANSI/ASABE S640

Horticultural lamp metrics and the DLC Horticultural QPL: Hort Americas

Photon-to-energy conversions calculated from photon energy at each wavelength using the Planck relation.

Educational content for B2B sourcing. Not engineering, safety or regulatory advice. Conversion values are calculated, not measured, and do not describe any product. Applicable safety standards depend on the device and its market. No medical claims are made.